ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
24
| System Management Commands
System Status
– 906 –
show startup-config This command displays the configuration file stored in non-volatile memory
that is used to start up the system.
COMMAND MODE
Privileged Exec
COMMAND USAGE
Use this command in conjunction with the show running-config
command to compare the information in running memory to the
information stored in non-volatile memory.
This command displays settings for key command modes. Each mode
group is separated by “!” symbols, and includes the configuration mode
command, and corresponding commands. This command displays the
following information:
MAC address for the switch
L2 Protocol Tunnel destination MAC
SNMP community strings
Users (names, access levels, and encrypted passwords)
VLAN database (VLAN ID, name and state)
VLAN configuration settings for each interface
Multiple spanning tree instances (name and interfaces)
IP address configured for management VLAN
Interface settings
Any configured settings for the console port and Telnet
EXAMPLE
Refer to the example for the running configuration file.
RELATED COMMANDS
show running-config (904)
show system This command displays system information.
DEFAULT SETTING
None
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
For a description of the items shown by this command, refer to
"Displaying System Information" on page 149.
There are three fans in the switch. Fans 1 - 3 are located from the font
to the back of the fan tray, and provide cooling for the power supply
and other internal components by forcing air out of the unit.