ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
24
| System Management Commands
System Status
– 903 –
switch through hard-wired connections described in the Installation
Guide. Refer to the Installation Guide for information on how to use the
alarm relay contacts and external site alarm inputs.
Major alarms include the failure of all fans, both thermal detectors
exceeding 65°C, or an invalid power module being installed. Minor
alarms include the failure of one or two fans, or when a second power
module is installed but it is not functioning.
EXAMPLE
The following shows the message types displayed when no alarms are
active, and another example when both minor and major alarms occur.
Console#show alarm-status
Unit 1
Asserted Alarm Input : [NONE]
Current Major Alarm Status:[NONE]
Current Minor Alarm Status:[NONE]
Current Major Alarm Output Status:[INACTIVE]
Current Minor Alarm Output Status:[INACTIVE]
Console#
show memory This command shows memory utilization parameters, and alarm
thresholds.
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
This command shows the amount of memory currently free for use, the
amount of memory allocated to active processes, and the total amount of
system memory.
EXAMPLE
Console#show memory
Status Bytes %
------ ---------- ---
Free 406712320 75
Used 130158592 25
Total 536870912
Alarm Configuration
Rising Threshold : 90%
Falling Threshold : 70%
Console#
RELATED COMMANDS
memory (1015)