ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
46
| OAM Commands
– 1606
DEFAULT SETTING
1
COMMAND MODE
Interface Configuration
COMMAND USAGE
If this feature is enabled, an event notification message is sent if the
threshold is reached or exceeded within the period specified by the efm
oam link-monitor frame window command. The Errored Frame Event TLV
includes the number of errored frames detected during the specified
period.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame threshold 5
Console(config-if)#
efm oam
link-monitor
frame window
This command sets the monitor period for errored frame link events. Use
the no form to restore the default setting.
SYNTAX
[no] efm oam link-monitor frame window size
size - The period of time in which to check the reporting threshold
for errored frame link events. (Range: 10-65535 units of 10
milliseconds)
DEFAULT SETTING
10 (units of 100 milliseconds) = 1 second
COMMAND MODE
Interface Configuration
COMMAND USAGE
If this feature is enabled, an event notification message is sent if the
threshold specified by the efm oam link-monitor frame threshold command
is reached or exceeded within the period specified by this command. The
Errored Frame Event TLV includes the number of errored frames detected
during the specified period.
EXAMPLE
This example set the window size to 5 seconds.
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame window 50
Console(config-if)#