ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
31
| Interface Commands
Transceiver Threshold Configuration
– 1213
supply voltage, laser bias current, laser power, received optical power,
and related alarm thresholds.
The DDM thresholds displayed by this command only apply to ports
which have a DDM-compliant transceiver inserted.
EXAMPLE
Console#show interfaces transceiver-threshold ethernet 1/25
Information of Eth 1/25
DDM Thresholds
Transceiver-monitor : Disabled
Transceiver-threshold-auto : Enabled
Low Alarm Low Warning High Warning High Alarm
----------- ------------ ------------ ------------ ------------
Temperature(Celsius) -123.00 0.00 70.00 75.00
Voltage(Volts) 3.10 3.15 3.45 3.50
Current(mA) 6.00 7.00 90.00 100.00
TxPower(dBm) -12.00 -11.50 -9.50 -9.00
RxPower(dBm) -21.50 -21.00 -3.50 -3.00
Console#