EXAMPLE
Console#show interfaces transceiver ethernet 1/25
Information of Eth 1/25
Connector Type : LC
Fiber Type : Multimode 50um (M5), Multimode 62.5um (M6)
Eth Compliance Codes : 1000BASE-SX
Baud Rate : 2100 MBd
Vendor OUI : 00-90-65
Vendor Name : FINISAR CORP.
Vendor PN : FTLF8519P2BNL
Vendor Rev : A
Vendor SN : PFS4U5F
Date Code : 09-07-02
DDM Info
Temperature : 11.54 degree C
Vcc : 3.25 V
Bias Current : 7.21 mA
TX Power : -4.37 dBm
RX Power : -31.55 dBm
DDM Thresholds
Low Alarm Low Warning High Warning High Alarm
----------- ------------ ------------ ------------ ------------
Temperature(Celsius) -123.00 0.00 70.00 75.00
Voltage(Volts) 3.10 3.15 3.45 3.50
Current(mA) 6.00 7.00 90.00 100.00
TxPower(dBm) -12.00 -11.50 -9.50! -9.00!
RxPower(dBm) -21.50! -21.00! -3.50 -3.00
Console#
show interfaces
transceiver-
threshold
This command Displays the alarm/warning thresholds for temperature,
voltage, bias current, transmit power, and receive power.
SYNTAX
S
YNTAX
show interfaces transceiver-threshold [interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28)
DEFAULT SETTING
Shows all SFP interfaces.
COMMAND MODE
Privileged Exec
COMMAND USAGE
The switch can display diagnostic information for SFP modules which
support the SFF-8472 Specification for Diagnostic Monitoring Interface
for Optical Transceivers. This information allows administrators to
remotely diagnose problems with optical devices. This feature, referred
to as Digital Diagnostic Monitoring (DDM) in the command display,
provides information on transceiver parameters including temperature,