| Interface Commands
Transceiver Threshold Configuration
– 1210
Low Warning: -21.00 dBm
Low Alarm: -21.50 dBm
COMMAND MODE
Interface Configuration (Ethernet)
COMMAND USAGE
The threshold value is the power ratio in decibels (dB) of the measured
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the transceiver-threshold
current command for more information on configuring transceiver
thresholds.
Trap messages enabled by the transceiver-threshold-monitor command
are sent to any management station configured by the snmp-server
host command.
EXAMPLE
The following example sets alarm thresholds for the signal power
transmitted at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold tx-power low-alarm 8
Console(config-if)#transceiver-threshold tx-power high-alarm -3
Console#
transceiver-
threshold voltage
This command sets thresholds for the transceiver voltage which can be
used to trigger an alarm or warning message.
SYNTAX
transceiver-threshold voltage {high-alarm | high-warning | low-
alarm | low-warning} threshold-value
high-alarm – Sets the high voltage threshold for an alarm
message.
high-warning – Sets the high voltage threshold for a warning
message.
low-alarm – Sets the low voltage threshold for an alarm message.
low-warning – Sets the low voltage threshold for a warning
message.
threshold-value – The threshold of the transceiver voltage.
(Range: 100-25500 in units of 0.01 Volt)
DEFAULT SETTING
High Alarm: 3.50 Volts
HIgh Warning: 3.45 Volts
Low Warning: 3.15 Volts
Low Alarm: 3.10 Volts