ECS4660-28F_Management Guide-R03

Table Of Contents
C
HAPTER
31
| Interface Commands
Transceiver Threshold Configuration
– 1208
DEFAULT SETTING
High Alarm: -3.00 dBm
HIgh Warning: -3.50 dBm
Low Warning: -21.00 dBm
Low Alarm: -21.50 dBm
COMMAND MODE
Interface Configuration (Ethernet)
COMMAND USAGE
The threshold value is the power ratio in decibels (dB) of the measured
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the transceiver-threshold
current command for more information on configuring transceiver
thresholds.
Trap messages enabled by the transceiver-threshold-monitor command
are sent to any management station configured by the snmp-server
host command.
EXAMPLE
The following example sets alarm thresholds for the signal power received
at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold rx-power low-alarm -21
Console(config-if)#transceiver-threshold rx-power high-alarm -3
Console#
transceiver-
threshold
temperature
This command sets thresholds for the transceiver temperature which can
be used to trigger an alarm or warning message.
SYNTAX
transceiver-threshold temperature {high-alarm | high-warning
| low-alarm | low-warning} threshold-value
high-alarm – Sets the high temperature threshold for an alarm
message.
high-warning – Sets the high temperature threshold for a warning
message.
low-alarm – Sets the low temperature threshold for an alarm
message.
low-warning – Sets the low temperature threshold for a warning
message.
threshold-value – The threshold of the transceiver temperature.
(Range: -20000 - 20000 in units of 0.01 Celsius)