CLI Reference Guide

Table Of Contents
Chapter 11
| Interface Commands
– 418 –
The test takes approximately 1 second. Use the show cable-diagnostics
command to display the results of the test, including common cable failures, as
well as the status and approximate length of each cable pair.
Potential conditions which may be listed by the diagnostics include those listed
below.
Pair busy, linked partner in 100BAS-TX forced mode
Interpair short
Intrapair short
Pair open, fault detected
Invalid, cable diagnostic routine did not complete successfully
Ports must have auto-negotiation enabled
Ports are linked down while running cable diagnostics.
This cable test is only accurate for Ethernet cables 7 - 100 meters long.
Ports are linked down while running cable diagnostics.
To ensure more accurate measurement of the length to a fault, first disable
power-saving mode (using the no power-save command) on the link partner
before running cable diagnostics.
Example
Console#test cable-diagnostics interface ethernet 1/21
Cable Diagnostics on interface Ethernet 1/21:
Cable OK with accuracy 10 meters.
Pair A OK, length 0 meters
Pair B OK, length 0 meters
Pair C OK, length 7 meters
Pair D Open, length 2 meters
Last Update 0n 2019-05-31 09:16:57
Console#
test loop internal
test loop internal This command performs an internal loop back test on the specified port.
Syntax
test loop internal interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (1-54)