Web Management Guide-R04

Table Of Contents
Chapter 13
| Basic Administration Protocols
Connectivity Fault Management
– 528 –
A change to the hold time only applies to entries stored in the database after
this attribute is changed.
MEP Fault Notify Lowest Priority – The lowest priority defect that is allowed
to generate a fault alarm. (Range: 1-6, Default: 2)
MEP Fault Notify Alarm Time – The time that one or more defects must be
present before a fault alarm is issued. (Range: 3-10 seconds; Default: 3
seconds)
MEP Fault Notify Reset Time – The time after a fault alarm has been issued,
and no defect exists, before another fault alarm can be issued. (Range: 3-10
seconds; Default: 10 seconds)
Web Interface
To create a maintenance domain:
1. Click Administration, CFM.
2. Select Configure MD from the Step list.
3. Select Add from the Action list.
4. Specify the maintenance domains and authorized maintenance levels (thereby
setting the hierarchical relationship with other domains).
5. Specify the manner in which MIPs can be created within each domain.
6. Click Apply.
Figure 340: Configuring Maintenance Domains
To show the configured maintenance domains:
1. Click Administration, CFM.
2. Select Configure MD from the Step list.
3. Select Show from the Action list.