ECS4110-28T_Management Guide

Table Of Contents
C
HAPTER
21
| System Management Commands
System Status
– 732 –
show system This command displays system information.
DEFAULT SETTING
None
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
For a description of the items shown by this command, refer to
"Displaying System Information" on page 123.
The ECS4110-28T/P has two fans and ECS4110-52T/P has three.
The ECS4110-28T/P does not monitor system temperature.
EXAMPLE
Console#show system
System Description : ECS4110-52T Managed GE Switch
System OID String : 1.3.6.1.4.1.259.10.1.39.101
System Information
System Up Time : 0 days, 7 hours, 20 minutes, and 43.30 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 00-E0-0C-00-00-FD
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
Unit 1
Fan 1: Ok Fan 2: Ok Fan 3: Ok
System Temperature:
Unit 1
Temperature 1: 48 degrees
Console#
show tech-support This command displays a detailed list of system settings designed to help
technical support resolve configuration or functional problems.
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
This command generates a long list of information including detailed
system and interface settings. It is therefore advisable to direct the output
to a file using any suitable output capture function provided with your
terminal emulation program.