SNMP trap destinations are defined using the snmp-server host
command.
Information about additional changes in LLDP neighbors that occur
between SNMP notifications is not transmitted. Only state changes that
exist at the time of a trap notification are included in the transmission.
An SNMP agent should therefore periodically check the value of
lldpStatsRemTableLastChangeTime to detect any lldpRemTablesChange
notification-events missed due to throttling or transmission loss.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#lldp notification
Console(config-if)#
show lldp config This command shows LLDP configuration settings for all ports.
SYNTAX
show lldp config [detail interface]
detail - Shows configuration summary.
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28/52)
port-channel channel-id (Range: 1-16)
COMMAND MODE
Privileged Exec
EXAMPLE
The following example shows all basic LLDP parameters are enabled on
Port 1.
Console#show lldp config
LLDP Global Configuration
LLDP Enabled : Yes
LLDP Transmit Interval : 30 seconds
LLDP Hold Time Multiplier : 4
LLDP Delay Interval : 2 seconds
LLDP Re-initialization Delay : 2 seconds
LLDP Notification Interval : 5 seconds
LLDP MED Fast Start Count : 4
LLDP Port Configuration
Port Admin Status Notification Enabled
-------- ------------ --------------------
Eth 1/1 Tx-Rx True
Eth 1/2 Tx-Rx True
Eth 1/3 Tx-Rx True