Cable Diagnostics
– 1018
This cable test is only accurate for Gigabit Ethernet cables 7 - 100
meters long.
The test takes approximately 5 seconds. The switch displays the results
of the test immediately upon completion, including common cable
failures, as well as the status and approximate length of each cable
pair.
Potential conditions which may be listed by the diagnostics include:
OK: Correctly terminated pair
Open: Open pair, no link partner
Short: Shorted pair
Not Supported: This message is displayed for Gigabit Ethernet ports
linked up at a speed lower than 1000 Mbps.
Impedance mismatch: Terminating impedance is not in the
reference range.
Ports are linked down while running cable diagnostics.
To ensure more accurate measurement of the length to a fault, first
disable power-saving mode (using the no power-save command) on the
link partner before running cable diagnostics.
EXAMPLE
Console#test cable-diagnostics interface ethernet 1/23
Console#show cable-diagnostics interface ethernet 1/23
TF: Test failed
OK: OK
ON: Open
ST: Short
IE: Impedance error
NC: No cable
NT: Not tested
NS: Not supported
UN: Unknown
Port Type Link Pair A Pair B Pair C Pair D Last
Status meters meters meters meters Updated
-------- ---- -------- -------- -------- -------- -------- ------------------
Eth 1/ 1 GE Up OK (0) OK (0) NS NS 2014-05-08 12:12:50
Console#
show cable-
diagnostics
This command shows the results of a cable diagnostics test.
SYNTAX
show cable-diagnostics interface [interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-24/48)