ECS4110-28T_Management Guide

Table Of Contents
C
HAPTER
27
| Interface Commands
Transceiver Threshold Configuration
– 1015
DEFAULT SETTING
High Alarm: 3.50 Volts
HIgh Warning: 3.45 Volts
Low Warning: 3.15 Volts
Low Alarm: 3.10 Volts
COMMAND MODE
Interface Configuration (SFP Ports)
COMMAND USAGE
Refer to the Command Usage section under the transceiver-threshold
current command for more information on configuring transceiver
thresholds.
Trap messages enabled by the transceiver-monitor command are sent
to any management station configured by the snmp-server host
command.
EXAMPLE
The following example sets alarm thresholds for the transceiver voltage at
port 1.
Console(config)interface ethernet 1/52
Console(config-if)#transceiver-threshold voltage low-alarm 4
Console(config-if)#transceiver-threshold voltage high-alarm 2
Console#
show interfaces
transceiver
This command displays identifying information for the specified transceiver,
including connector type and vendor-related parameters, as well as the
temperature, voltage, bias current, transmit power, and receive power.
SYNTAX
show interfaces transceiver [interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 25-28/49-52)
DEFAULT SETTING
Shows all SFP interfaces.
COMMAND MODE
Privileged Exec
COMMAND USAGE
The switch can display diagnostic information for SFP modules which
support the SFF-8472 Specification for Diagnostic Monitoring Interface for
Optical Transceivers. This information allows administrators to remotely