ECS4100 Series CLI Reference Guide-R07

Table Of Contents
Chapter 11
| Interface Commands
Cable Diagnostics
– 430 –
show
cable-diagnostics
This command shows the results of a cable diagnostics test.
Syntax
show cable-diagnostics interface [interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10/22/24/48)
Command Mode
Privileged Exec
Command Usage
The results include common cable failures, as well as the status and
approximate distance to a fault, or the approximate cable length if no fault is
found.
To ensure more accurate measurement of the length to a fault, first disable
power-saving mode on the link partner before running cable diagnostics.
For link-down ports, the reported distance to a fault is accurate to within +/- 2
meters. For link-up ports, the accuracy is +/- 10 meters.
Potential conditions which may be listed by the diagnostics are shown by the
legend in the following example. Additional information is provided for the
following test results.:
OK: Correctly terminated pair
ON: Open pair, no link partner
IE (Impedance mismatch): Terminating impedance is not in the reference
range.
NS (Not Supported): This message is displayed for any Gigabit Ethernet
ports linked up at a speed lower than 1000 Mbps.
UN: Unknown Error
Example
Console#show cable-diagnostics interface
TF: Test failed
OK: OK
ON: Open
ST: Short
IE: Impedance error
NC: No cable
NT: Not tested
NS: Not supported
UN: Unknown
Port Type Link Pair A Pair B Pair C Pair D Last
Status meters meters meters meters Updated
-------- ---- -------- -------- -------- -------- -------- ------------------
-