Management Guide R05

Table Of Contents
C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 538 –
Level – Authorized maintenance level for this domain.
Direction – Direction in which the MEP communicates CFM messages:
Down indicates that the MEP is facing away from the switch, and
transmits CFM messages towards, and receives them from, the
direction of the physical medium.
Up indicates that the MEP faces inward toward the switch cross-
connect matrix, and transmits CFM messages towards, and receives
them from, the direction of the internal bridge relay mechanism.
Primary VLAN – Service VLAN ID.
Interface – Physical interface of this entry (either a port or trunk).
CC Status – Shows administrative status of CCMs.
MAC Address – MAC address of this MEP entry.
WEB INTERFACE
To show information for the MEPs configured on this device:
1. Click Administration, CFM.
2. Select Show Information from the Step list.
3. Select Show Local MEP from the Action list.
Figure 308: Showing Information on Local MEPs
DISPLAYING DETAILS
FOR
LOCAL MEPS
Use the Administration > CFM > Show Information (Show Local MEP
Details) page to show detailed CFM information about a local MEP in the
continuity check database.
CLI REFERENCES
"show ethernet cfm maintenance-points local detail mep" on page 1328
PARAMETERS
These parameters are displayed:
MD Index – Domain index. (Range: 1-65535)
MA Index – MA identifier. (Range: 1-2147483647)
MEP ID – Maintenance end point identifier. (Range: 1-8191)