Management Guide R05

Table Of Contents
C
HAPTER
14
| Basic Administration Protocols
Connectivity Fault Management
– 528 –
5. Specify the CCM interval, enable the transmission of connectivity check
and cross check messages, and configure the required AIS parameters.
6. Click Apply
Figure 300: Configuring Detailed Settings for Maintenance Associations
CONFIGURING
MAINTENANCE
END POINTS
Use the Administration > CFM (Configure MEP – Add) page to configure
Maintenance End Points (MEPs). MEPs, also called Domain Service Access
Points (DSAPs), must be configured at the domain boundary to provide
management access for each maintenance association.
CLI REFERENCES
"CFM Commands" on page 1311
COMMAND USAGE
CFM elements must be configured in the following order: (1)
maintenance domain at the same level as the MEP to be configured
(see "Configuring CFM Maintenance Domains"), (2) maintenance
association within the domain (see "Configuring CFM Maintenance
Associations"), and (3) finally the MEPs using the MEP List.
An interface may belong to more than one domain, or to different MAs
in different domains.
To change the MEP’s MA or the direction it faces, first delete the MEP,
and then create a new one.
PARAMETERS
These parameters are displayed:
MD Index – Domain index. (Range: 1-65535)
MA Index – MA identifier. (Range: 1-2147483647)