ECS3510-26P_Management Guide R02

Table Of Contents
C
HAPTER
20
| System Management Commands
System Status
– 530 –
Any configured settings for the console port and Telnet
EXAMPLE
Refer to the example for the running configuration file.
RELATED COMMANDS
show running-config (528)
show system This command displays system information.
DEFAULT SETTING
None
COMMAND MODE
Normal Exec, Privileged Exec
COMMAND USAGE
For a description of the items shown by this command, refer to
"Displaying System Information" on page 97.
The POST results should all display “PASS.” If any POST test indicates
“FAIL,” contact your distributor for assistance.
EXAMPLE
Console#show system
System Description : ECS3510-26P Managed FE POE Switch
System OID String : 1.3.6.1.4.1.259.10.1.38.104
System Information
System Up Time : 0 days, 7 hours, 20 minutes, and 43.30 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 00-E0-0C-00-00-FD
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
System Fan:
Unit 1
POST Result:
Console#