Web Management Guide-R07

Table Of Contents
Chapter 4
| Interface Configuration
Port Configuration
– 121 –
A low-threshold alarm or warning message is sent if the current value is less
than or equal to the threshold, and the last sample value was greater than
the threshold. After a falling event has been generated, another such event
will not be generated until the sampled value has risen above the low
threshold and reaches the high threshold.
Threshold events are triggered as described above to avoid a hysteresis
effect which would continuously trigger event messages if the power level
were to fluctuate just above and below either the high threshold or the low
threshold.
Trap messages configured by this command are sent to any management
station configured as an SNMP trap manager using the Administration >
SNMP (Configure Trap) page.
Web Interface
To configure threshold values for optical transceivers:
1. Click Interface, Port, Transceiver.
2. Select a port from the scroll-down list.
3. Set the switch to send a trap based on default or manual settings.
4. Set alarm and warning thresholds if manual configuration is used.
5. Click Apply.
Figure 43: Configuring Transceiver Thresholds