CLI Reference Guide-R07

Table Of Contents
Chapter 1
| Initial Switch Configuration
Configuring the Switch for Cloud Management
– 54 –
ND advertised reachable time is 0 milliseconds
ND advertised router lifetime is 1800 seconds
Console#
Configuring the Switch for Cloud Management
The Edgecore ecCLOUD Controller is a cloud-based network service available from
anywhere through a web-browser interface. The switch can be managed by the
ecCLOUD controller once you have set up an account and registered the device on
the system.
By default, the cloud management agent is disabled on the switch. Setting the
cloud management agent to enabled allows the switch to be managed through the
ecCLOUD system after the next reboot.
To enable the cloud management agent, log into the CLI and use the mgmt enable
command from the Global Config level. Then reboot the switch to initiate
communications with the ecCLOUD controller.
Username: admin
Password:
CLI session with the ECS2100-28T is opened.
To end the CLI session, enter [Exit].
Console#configure
Console(config)#mgmt enable
Console(config)#exit
Console#reload
System will be restarted, continue <y/n>? y
For more information on cloud management configuration, see “Cloud
Management” on page 91.
Enabling SNMP Management Access
The switch can be configured to accept management commands from Simple
Network Management Protocol (SNMP) applications such as Edge-Core ECView Pro.
You can configure the switch to respond to SNMP requests or generate SNMP traps.
When SNMP management stations send requests to the switch (either to return
information or to set a parameter), the switch provides the requested data or sets
the specified parameter. The switch can also be configured to send information to
SNMP managers (without being requested by the managers) through trap
messages, which inform the manager that certain events have occurred.