If sufficient power cannot be made available by turning off power to lower-
priority ports, power may not be supplied to a device connected to a high
or critical priority port.
The priority setting will be ignored if a device is connected to a port after the
switch has finished booting up. When a newly connected device causes the
switch to exceed its budget, power will not be provided to that devices port
regardless of its priority setting.
If priority is not set for any ports, and PoE consumption exceeds the
maximum power provided by the switch, power is shut down in reverse
sequence from port number 8 or 24.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#power inline priority 2
Console(config-if)#
power inline
time-range
This command binds a time-range to a port during which PoE is supplied to the
attached device. Use the no form to remove this binding.
Syntax
power inline time-range time-range-name
no power inline time-range
time-range-name - Name of the time range. (Range: 1-32 characters)
Default Setting
None
Command Mode
Interface Configuration
Example
Console(config)#interface ethernet 1/1
Console(config-if)#power inline time-range rd
Console(config-if)#
Related Commands
time-range (159)
power download Use this command to download an Edgecore compiled firmware file to the
onboard PoE IC.