ECIS4500 series Web Management Guide R02

Command Descriptions
309
configuration. To diagnose, paste the receiver's IP address/hostname into the Ping
Web page (Diagnostics → Ping/Ping6).
Flow Samples
The total number of flow samples sent to the sFlow receiver.
Counter Samples
The total number of counter samples sent to the sFlow receiver.
Port Statistics
Port
The port number for which the following statistics applies.
Rx and Tx Flow Samples
The number of flow samples sent to the sFlow receiver originating from this port.
Here, flow samples are divided into Rx and Tx flow samples, where Rx flow samples
contains the number of packets that were sampled upon reception (ingress) on the
port and Tx flow samples contains the number of packets that were sampled upon
transmission (egress) on the port.
Counter Samples
The total number of counter samples sent to the sFlow receiver originating from this
port.
Buttons
Check this box to refresh the page automatically. Automatic refresh occurs every 3
seconds.
Click to refresh the page.
Clears the sFlow receiver counters.
Clears the per-port counters.
2.4.80 RingV2