ECIS4500 Series CLI Reference Guide R02
77
3.15.3 loop-protect shutdown-time
Description
Loop protection shutdown time interval
Syntax
loop-protect shutdown-time <0-604800>
Parameter
Name
Description
0-604800
Shutdown time in second
3.15.4 loop-protect transmit-time
Description
Loop protection transmit time interval
Syntax
loop-protect transmit-time <1-10>
Parameter
Name
Description
1-10
Transmit time in second
3.15.5 loop-protect tx-mode
Description
Loop protection actively generate PDUs
Syntax
loop-protect tx-mode
Parameter
3.16 LLDP Configure commands
3.16.1 lldp holdtime
Description
Sets LLDP hold time (The neighbor switch will discarded the LLDP
information after \"hold time\" multiplied with \"timer\" seconds ).
Syntax
lldp holdtime <2-10>
Parameter
Name
Description
<2-10>
Holdtime 2-10 seconds
3.16.2 lldp med
Description
LLDP MED
Syntax
See Description
Parameter
Name
Description
datum
Datum (geodetic system) type
nad83-mllw
Mean lower low water datum
1983
nad83-navd88
North American vertical datum
1983
wgs84
World Geodetic System 1984
fast
Number of times to repeat LLDP frame
transmission at fast start
<v_1_to_10> : <1-10>
location-tlv
LLDP-MED Location Type Length Value parameter
altitude
Altitude parameter
civic-addr
Civic address information and postal
information