(AS9716-32D) Quick Start Guide R02
Quick Start Guide
– 3 –
Connect Timing Ports
Make Management Connections
4
1PPS and 10 MHz Ports
Use coax cables to connect the 1-pulse-per-second (1PPS) and
10 MHz IN/OUT ports to other synchronized devices.
ToD Port
Use a shielded cable to connect the Time-of-Day (ToD) port to other
devices that use ToD synchronization signals.
5
10/100/1000M RJ-45 Management Port
Connect Cat. 5e or better twisted-pair cable.
10G SFP+ Management Ports
Install transceivers and then connect fiber optic cabling to the
transceiver ports.
RJ-45 Console Port
Connect the included console cable and then configure the serial
connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data
bits, and no flow control.
Hardware Specifications
Switch Chassis
Size (WxDxH) 438.4 x 536 x 43.1 mm (17.26 x 21.1 x 1.7 in.)
Weight 11.06 kg (24.38 lb), with 2 PSUs and 6 fans installed
Temperature Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power
Consumption
1300 Watts maximum
AC PSU
Input Power
Rating
100–120 VAC, 50–60 Hz, 12 A max.
200–240 VAC, 50–60 Hz, 7.5 A max.
190–310 VDC, 8–5 A
Regulatory Compliances
Emissions EN 55032:2015+AC:2016, Class A
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CCC GB 9254-2008, Class A
Immunity EN 55035:2017
EN 55024:2010+A1:2015
IEC 61000-4-2/3/4/5/6/8/11
Safety UL (CSA 22.2 No 62368-1 & UL62368-1)
CB (IEC/EN60950-1 & IEC/EN 62368-1)
CCC GB4943.1-2011