Connect Network Cables
1. For the RJ-45 Management port, connect 100-ohm Category 5,
5e or better twisted-pair cable.
2. Connect DAC cables to the QSFP28 slots. Or fi
rst install
Q
SFP28 transceivers in the slots and then conn
ect fiber optic
cablin
g to the transceiver po
rts.
3. Co
nnect fiber optic cabling to the coherent
optical CFP2
tran
sceiver ports.
4. As connections are made, check the port status LEDs to be sure
the links are valid.
Each QSFP28 port has four LEDs that indicate valid links in the
following modes:
1 LED Blue — 100 Gbps mode
1 LED Orange — 40 Gbps mode
1-4 LEDs White — 25 Gbps breakout mode (four lanes)
1-4 LEDs Green — 10 Gbps breakout mode (four lanes)
For the ACO or DCO CFP2 ports:
Blue — 200 Gbps link
Green — 100 Gbps link
Hardware Specifications
9
2
1
3
4
Switch Chassis
Size (WxDxH) 442.5 x 550 x 66 mm (17.42 x 21.65 x 2.6 in.)
Weight 11.6 kg (25.57 lb), with two installed PSUs
Temperature Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power
Consumption
1035 Watts maximum
AC PSU
Power Rating 100–127 VAC, 50/60 Hz, 800 Watts maximum
200–240 VAC, 50/60 Hz, 1200 Watts maximum
AC Input 100–127 VAC, 50/60 Hz, 10.0 A maximum
200–240 VAC, 50/60 Hz, 8.0 A maximum
Regulatory Compliances
Emissions EN 55032:2015+AC:2016, Class A
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CCC GB 9254-2008, Class A
Immunity EN 55024:2010+A1:2015
IEC 61000-4-2/3/4/5/6/8/11
Safety UL (CSA 22.2 No 60950-1 & UL60950-1)
CB (IEC/EN60950-1)
CCC GB4943.1-2011