Set Point The set-point for the queue. This is the target number of octets in the CP’s
queue. (Default: 26000)
Feedback Weight Variable used in calculation or Quantized Feedback and New Sample Base. If
the queue length is moving toward the set point, the feedback weight will be
closer to 0 than if the queue length is moving away from the set point.
Minimum Sample
Base
The minimum number of octets to enqueue in the CP’s queue between CNM
PDU transmissions. (Default: 150,000 bytes)
Discarded Frames The number of frames offered to this CP that were discarded because of a full
output queue.
Transmitted Frames The number of data frames enqueued for transmission on this CP’s output
queue.
Transmitted CNMs The number of CNMs transmitted by this CP.
Table 109: show cn cp - display description (Continued)