AS5800-EC Series CLI Reference Guide R02

Table Of Contents
Chapter 2
| Initial Switch Configuration
Connecting to the Switch
– 62 –
System Contact :
MAC Address (Unit 1) : A8-2B-B5-76-B0-CE
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
Unit 1
Fan 1: Fail Fan 2: Fail Fan 3: Fail
Fan 4: Fail Fan 5: Fail
System Temperature:
Unit 1
Temperature 1: 24 degrees Temperature 2: 31 degrees
Temperature 3: 28 degrees Temperature 4: 26 degrees
Main Power Status : Up
Redundant Power Status : Down
...
To install a license, first verify that the craft port is configured with a valid IP address
using the “show interface” command. If no information is displayed for the craft
interface, use the ”ip address” command to configure the IP address for the craft
port as shown in the following example:
Console#configure
Console(config)#interface craft
Console(config-if)#ip address 192.168.0.200 255.255.255.0
Console(config-if)#
Download the corresponding license file as shown in the following example. Note
that the license file is named according to the device MAC address. The network
ports will be automatically activated within two minutes after successful
installation.
Console#copy tftp file
TFTP server IP address: 192.168.0.102
Choose file type:
1. config; 2. opcode; 3. license: 3
Source file name: 7072CFEB9CE4.lic
Flash programming started.
Flash programming completed.
Success.
To display information on the installed file, enter the “show license file” command.
Console#show license file
aos-license/1.0
Name: Tech Writer
CPU-MAC-Address: A8-2B-B5-76-B0-CE
Project-Number: AOS5810-54X