AS5800-EC Series CLI Reference Guide R02

Table Of Contents
Chapter 11
| Interface Commands
Interface Configuration
– 363 –
Example
Console#hardware profile portmode ethernet 1/1 4x10g
Console#
show hardware profile
portmode
This command displays the configuration settings for 40G operation.
Command Mode
Privileged Exec
Example
This example shows the default 40G and 10G port settings for the AS5812-54X-EC.
Console#show hardware profile portmode
40G 10G Config Oper
Interfaces Interfaces Mode Mode
---------- ---------- ------ ------
1/1 1/1-4 - 4x10g
1/5 1/5-8 - 4x10g
1/9 1/9-12 - 4x10g
1/13 1/13-16 - 4x10g
1/17 1/17-20 - 4x10g
1/21 1/21-24 - 4x10g
1/25 1/25-28 - 4x10g
1/29 1/29-32 - 4x10g
1/33 1/33-36 - 4x10g
1/37 1/37-40 - 4x10g
1/41 1/41-44 - 4x10g
1/45 1/45-48 - 4x10g
1/49 1/55-58 - 1x40g
1/50 1/59-62 - 1x40g
1/51 1/63-66 - 1x40g
1/52 1/67-70 - 1x40g
1/53 1/71-74 - 1x40g
1/54 1/75-78 - 1x40g
Console#
show interfaces brief This command displays a summary of key information, including operational
status, native VLAN ID, default priority, speed/duplex mode, and port type for all
ports.
Command Mode
Privileged Exec
Example
Console#show interfaces brief
Interface Name Status PVID Pri Speed/Duplex Type Trunk
--------- ----------------- --------- ---- --- ------------- ------------ -----
Eth 1/ 1 Up 1 0 Auto-1000full 1000BASE SFP None
Eth 1/ 2 Up 1 0 1000full 1000BASE SFP None
Eth 1/ 3 Down 1 0 10Gfull 10GBASE SFP+ None
.