Hardware Specifications
Interfaces
Management 1 x RJ-45 Console port
1 x RJ-45 10/100/1000BASE-T Management port
1 x USB2.0 Port
1 x Micro USB Console port
Network 18 x 100G QSFP28
4 x 400G QSFP-DD
4 x 100G QSFP-DD
4 x 10G/25G SFP28
Chassis
Size (WxDxH) 440 x 524 x 87 mm (17.3 x 20.6 x 3.4 in)
Weight 14.5 kg (31.96 lb)
Operating
Temperature
0° C to 45° C (32° F to 113° F)
Storage
Temperature
-40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% (non-condensing)
Storage: 5% to 95% (non-condensing)
Power
Consumption
638 W at 25° C (77° F)
695 W at 45° C (113° F)
48 VDC PSU
DC Input -40 – -75 VDC, 40 A max
AC PSU
AC Input 100-120 V~, 50-60 Hz, 12 A Max.
200-240 V~, 50-60 Hz, 7.5 A Max.
Regulatory Compliances
Emissions EN 55032:2015+A1:2020
EN 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A1:2019
FCC Part 15 subpart B Class A
CCC (GB9254-2008)
BSMI
VCCI
Immunity EN 55024:2010+A1:2015
EN 55035:2017+A11:2020
IEC 61000-4-2/3/4/5/6/8/11
Safety UL/CUL (CAN/CSA22.2 No 62368-1 & UL 62368-1)
CB (IEC/EN 60950-1 & IEC/EN 62368-1)
CCC (GB4943.1-2011)
BSMI
VCCI
Taiwan RoHS CNS 15663