Specifications

Electrified Options & Accessories
ED5000.39
ED5000 Series Pushpad Exit Devices
BLU
WHT/YEL
YEL
NC
COM
NO
GRAY
WHT/BRN
BRN
NC
COM
NO
VIO
WHT/ORG
ORG
NC
COM
NO
Bolt Position Monitoring - M91
Provides indication of the position of the
latch bolt. Used with security systems to
monitor the latch bolt; also used to
activate automatic door operators upon
latch retraction.
Application
See chart on page 32.
Listings
UL listed for both Panic and Fire Exit
Hardware.
Electrical Specifications
5 Amps @ 28VDC SPDT contacts
Ordering
Specify Quick Code M91.
Touchbar Monitoring - M92
Provides indication of the pushpad being
depressed. Used as a request to exit to
shunt alarm systems, release
electromagnetic locks or monitor egress.
Application
See chart on page 32.
Listings
UL listed for both Panic and Fire Exit
Hardware.
Electrical Specifications
4 Amps @ 250 VAC contacts
Ordering
Specify Quick Code M92.
Outside Monitoring or Signaling - M93
Provides indication of the device being
operated from the outside. Used as a
request to enter signal switch to shunt
alarms; also used to monitor entry.
Application
See chart on page 32.
Listings
UL listed for both Panic and Fire Exit
Hardware.
Electrical Specifications
5 Amps @ 28VDC SPDT contacts
Ordering
Specify Quick Code M93.
Monitors - M91, M92, M93
Operation
Monitors are used to indicate the authorized and unauthorized use of an opening or to signal and control other opening hardware,
such as magnetic locks. Each monitoring device is equipped with one internal single-pole double-throw (SPDT) switch per monitor.
781N Controller
Operation
Designed to control one or two electric
latch pullback M94 exit devices. Equipped
with two 20-second timers which can
operate the exit devices together or
independently. Requires a momentary or
timed, dry contact input and can be
interfaced with access control systems,
automatic door operators, “blow open”
type scenarios and has provisions for N/C
fire alarm systems.
Features
•2 control inputs. Accepts normally
closed dry contacts for device activation
from a key switch, push button, access
control or fire alarm system.
•2 normally open control outputs for
automatic door operators
•2 M94 device outputs
Fire Alarm Interface input
12VDC output for audible or LEDS
.25 AMP
24VDC output for audible or LEDS
.25 AMP
Wiring
Up to 40 feet: 16 AWG wire
Up to 60 feet: 14 AWG wire
Up to 100 feet: 12 AWG wire
Electrical Specifications
120 or 240VAC 60 Hz Power input
•9 Amp inrush for 100 milliseconds
Holding voltage @ 28volts unregulated
Listings
Listed as an Exit Device Control Unit to
UL 294 requirements.
Note: The 781N is the only power source
to be used with the M94 option. Using
any other power supply will void the
warranty and cause possible damage to
the exit device.
Ordering
781N-120 Controller (120VAC input)
EPTL
Concealed power transfer for over 120°
swing doors. Installs in door and frame
edges. Supports wires up to .25" (6mm)
thick, and works with doors hung with
butt hinges, continuous hinges and
pivots. To order, specify Part No. 704F28
781N-240 Controller (240VAC input)
781N Controller