User guide
D
8: Slide the housing to desired position. If necessary loosen the
wing nuts to ease the sliding. After the desired position is
achieved tighten all the wing nuts.
8
8
E
9
9: Loosen the four #8-32 screws on the front of the housing.
10: Remove the trim and cover from the housing.
TRIM
9
COVER
#8-32 SCREW
10
11: Remove a knock out to install the power line conduit.
12: Install the conduit and run the power line wires to the
housing.
13: (OPTIONAL)-If using slave housings (Maximum 25 Slave
Housings), repeat step 1 through 10 on pages 1 and 2 for
each slave housing; run conduits for the low voltage wires
in sequence from the master housing and slave housing to
the adjacent slave housing.
14: Make sure that the housing is grounded in accordance
with local electrical codes.
15: Connect the LED power supply white wire to the power line
neutral wire with a wire nut.
16: Connect the LED power supply black wire to the power line
hot wire with a wire nut.
17: If using slave housings, then follow the "Slave Step Kit
Wiring" steps; otherwise follow "Install the Drywall, Trim &
Lamp" steps on page 4.
THERMAL
PROTECTOR
LED POWER SUPPLY
F
14
15
16
NOTE: Maximum 25 Slave step kits can be powered from a
master step kit. It is recommended to install the master step kit in
the middle of the run powering the slaves on both sides to reduce
voltage drop. The last step slave kit should not be more than 20ft
away from the master kit.
12
LOW VOLTAGE WIRE SIZE CHART
POWER SUPPLY
WATTAGE
WIRE SIZE FOR
UP TO 13 FT
WIRE SIZE
FOR 14-20 FT
WIRE SIZE
FOR 21-34 FT
WIRE SIZE
FOR 35-52 FT
60 WATT #14 GA #12 GA #10 GA #8 GA
13
2
OPTIONAL CONDUIT
TO SLAVE HOUSING