Owner's manual
SAVE THESE INSTRUCTIONS!
MPD-4RD-A-_
- This product is ETL listed for indoor dry locations.
- This product can be installed to a 4" electrical box with
round plaster ring, or to an octagon electrical box.
- Minimum electrical box volume must be 6 cubic inches
(98 cubic centimeters).
- This product should be installed by a qualified electrician.
Installation Instructions for Monorail 4" Round Dual Power Feed Canopy
With 12' Adjustable Power Feed Wires
1
904-MPD-4RD-A-03
IMPORTANT INFORMATION
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
info@edgelighting.com
A
Install the Canopy
2MM ALLEN WRENCH
M4 SET
SCREW
POWER CORD
1: Loosen the four M4 set screws on the plastic disk with the
2 mm Allen wrench provided.
2: Adjust the power feed wires to the desired height (from top
of the canopy to top of the Monorail - Illustrated as "H" in
diagram A) by pushing the power feed wires into the canopy.
3: Tighten the four M4 set screws firmly with the 2mm Allen
wrench.
4: Leave at least 6" of the power feed wires behind the canopy.
Trim off the excess power feed wires with a sharp cutter.
Strip 1/4" of insulation off of the power feed wires.
PLASTIC DISK
B
1
3
2
NOTE: Use the universal round crossbar (provided) if the electrical
box holes are not spaced 2-3/4" apart.
NOTE: The low voltage wires should be present in the electrical
box. Refer to the instructions provided with the remote
transformer to install the transformer and the low voltage wires
before proceeding with the steps below.
4
H
5: Turn the power to electrical box off.
6: Starting with left power housing, connect the wire that is
attached to the center contact to the transformer wire
marked "HOT 1" with a wire nut.
7: Connect the remaining wire of the left power housing to the
transformer wire marked "COM 1" with a wire nut.
8: Connect the wire of the right power housing that is attached
to the center contact to the transformer wire marked
"HOT 2" with a wire nut.
9: Connect the remaining wire of the right power housing to
the last transformer wire marked "COM 2" with a wire nut.
HOT 1
COM 1
HOT 2
COM 2
CENTER
WIRE
6
7
8
9
LEFT POWER
HOUSING WIRES
RIGHT POWER
HOUSING WIRES
© 2009 Edge Lighting. All Rights Reserved.