Specifications
4
RG SERIES ENGINEERING GUIDE
Model Nomenclature
RG S
1-2 4 5-7 8 9 10
Model Type
RG – RG Series
Operation Range
S – Single Stage
Cabinet Configuration
V – Vertical
H - Horizontal
Unit Capacity (MBTUH)
009, 012, 015, 018,
023 (horizontal),
024, 030, 036,
041 (vertical)
042, 048, 060, 070
Discharge Configuration
T – Top (Vertical)
E – End (Horizontal)
S – Side (Horizontal)
Return Air Configuration
L – Left
R – Right
Voltage
0 – 208-230/60/1
2 – 265-277/60/1 (009-030)
3 – 208-230/60/3 (023-070)
4 – 460/60/3 (023-070)
5 – 575/60/3 (PSC Only 041-070)
Hot Wire Generator Option
0 – No HWG, No GeoStart
®
2 – HWG w/o pump, No GeoStart (V015-070)
3 – No HWG, GeoStart
5 – HWG w/o pump, GeoStart (V024-070)
Blower Options
0 – PSC Blower
1 – Variable Speed ECM Blower (015-070)
2 – High Static Variable Speed ECM Blower (042-048)
3 – High Static PSC Blower (024, 030, 042, 048)
4 – 5-Speed ECM Blower (015-070)
Water Coil Option
C – Copper
N – CuproNickel
Sound Kit Option
A – None
B – Sound Kit (Not Available on H009-012)
Vintage
* - Factory Use Only
Non-Standard Options
SS – Standard
Drain Pan Option
0 – Composite, No Secondary Connection
1 – Composite, Secondary Connection
2 – Stainless Steel, No Secondary Connection
3 – Stainless Steel, Secondary Connection
Cabinet Option
0 – Unpainted, 1 in MERV 4, Filter Rail
1 – Painted, 1 in MERV 4, Filter Rail
2 – Unpainted, 2 in MERV 13, Filter Rail
3 – Painted, 2 in MERV 13, Filter Rail
4 – Unpainted, 1 in MERV 4, Filter Rack
5 – Painted, 1 in MERV 4, Filter Rack
6 – Unpainted, 2 in MERV 13, Filter Rack
7 – Painted, 2 in MERV 13, Filter Rack
Phase Guard
N – No Phase Guard, No Disconnect
P – Phase Guard, No Disconnect
B – Phase Guard, Disconnect
D – No Phase Guard, Disconnect
All-Aluminum Air Coil Option
5 – AlumiSeal
TM
, Extended Range
6 – AlumiSeal, Standard Range
7 – No Coating, Extended Range
8 – No Coating, Standard Range
Control Option
A – Aurora
TM
Base Control (ABC)
4 – FX10 std. No Communications
5 – FX10 w/ Open N2 Com Card
6 – FX10 w/ LonWorks Com Card
7 – FX10 w/ BacNet Com Card
Water Control Option
N – None
R – Water Flow Regulator (015-070)
V – 2-Way Valve (015-070)
B – 2-Way Valve w/ Water Flow Regulator
(015-070)
Refrigeration Option
N – None
G – Hot Gas Bypass (015-072)
R – Hot Gas Reheat (015-072)
B – Hot Gas Bypass w/Hot Gas Reheat (015-072)
Rev.: 29 October 2013D
11 12 13 15
V 036 T L 0 0 0 C A N
14
N
16
A
17
5
18
N
19
0
20
0
21
SS
22-23
*
24
Note: Phase Guard Only Available on 208-230/60/3, 460/60/3, and 575/60/3
50VA Transformer with Aurora and 75VA Transformer with FX10
3