Installation guide

– 19 –
3 Wireless Controller Chassis
The wireless controller is designed to be installed in a standard 19-inch equipment
rack.
Before continuing with installation, first review the general guidelines and unit
cooling requirements in this chapter.
This chapter includes these sections:
“General Installation Guidelines” on page 19
“How to Install the Unit in a Rack” on page 20
“Unit Cooling Requirements” on page 22
General Installation Guidelines
Be sure to follow the guidelines below when choosing a location.
The installation location should:
be able to maintain its temperature within 0 to 40 °C (32 to 104 °F) and its
humidity within 5% to 95%, non-condensing.
provide adequate space (approximately five centimeters or two inches) on
all sides for proper air flow.
be accessible for installing, cabling and maintaining the device.
allow the status LEDs to be clearly visible.
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference, such as
radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet and
is powered from an independent circuit breaker. As with any equipment, using
a filter or surge suppressor is recommended.