Installation guide
Command Line Interface
4-20
4
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure company
command interprets spaces as data input boundaries. The use of underscores
( _ ) or other unobtrusive non-letter characters is suggested for situations
where white space is necessary for clarity.
Example
banner configure dc-power-info
This command is use to configure DC power information displayed in the banner.
Use the no form to restore the default setting.
Syntax
banner configure dc-power-info floor floor-id row row-id rack rack-id
electrical-circuit ec-id
no banner configure dc-power-info [floor | row | rack | electrical-circuit]
• floor-id - The floor number.
• row-id - The row number.
• rack-id - The rack number.
• ec-id - The electrical circuit ID.
Maximum length of each parameter: 32 characters
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure dc-power-info
command interprets spaces as data input boundaries. The use of underscores
( _ ) or other unobtrusive non-letter characters is suggested for situations
where white space is necessary for clarity.
Example
Console(config)#banner configure company Edge-Core_Corporation
Console(config)#
Console(config)#banner configure floor 3 row 15 rack 24
electrical-circuit 48v-id_3.15.24.2
Console(config)#