Installation guide
C
HAPTER
4
| Making Network Connections
Twisted-Pair Devices
– 50 –
CONNECTING TO PCS, SERVERS, HUBS AND SWITCHES
1. Connect one end of a twisted-pair cable segment to the device’s RJ-45
connector.
Figure 18: Making Twisted-Pair Connections
2. If the device is a network card and the switch is in the wiring closet, attach
the other end of the cable segment to a modular wall outlet that is
connected to the wiring closet. (See the section "Network Wiring
Connections" on page 51.) Otherwise, attach the other end to an available
port on the switch.
Make sure each twisted pair cable does not exceed 100 meters (328 ft) in
length.
3. As each connection is made, the Link LED (on the switch) corresponding to
each port will turn on (green or amber) to indicate that the connection is
valid.
N
OTE
:
Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure jamming
signals may degrade overall performance for the segment attached to
the hub.