Installation guide

C
HAPTER
1
| Introduction
Description of Hardware
– 28 –
POWER SUPPLY INLET
There is one power inlet on the rear panel of the switch. The standard power
inlet is for the AC power cord.
Figure 3: Power Supply Inlet
GROUNDING POINT
To prevent accidental electrical shock or damage to your switch, it is
recommended that you ground the switch to an earth point by attaching a
grounding wire (not supplied) to the grounding point located next to the power
inlet, with a metal screw. If located in a tall building, grounding points include
metal drain pipes, and other electrostatic conductive devices that lead to the
ground, or if located on the first floor of a building, the ground outside itself.
RESET BUTTON
If you encounter any switch malfunctions, such as a hang or non-recoverable
error, you might want to reset the switch to its default configuration by pressing
and holding the reset button for five seconds. The reset button is located on the
rear panel on the opposing side of the power inlet.
Figure 4: Reset Button