Use and Care Manual
7
one step , it will cycle as below : 90%-85%-80%-75%-70%-65%-60%-55%-50%-45%-40%-35%-30%-
25%-20%-15%-10%-90% …When setting the timing data , press the button for one time to decrease
1 hour , it will cycle as below:24-23-22-21-20…-02-01-00-24-23…
It displays the running time when it is in running mode; and displays the setting timing and setting
humidity data when users set .
Minus Button: Press the Minus button to decrease humidity data or decrease
timing data . When setting the humidity data , press the button for one time to
decrease 5% RH , you can set the humidity range from 90%-10% RH, and 5% RH for
Purge Button (Manual Drainage):Press and hold the purge button for 3 seconds,
the machine will drain the water automatically by the built-in pump.
After 30 seconds, the pump stops draining, then the indicator will turn off.
Display Screen:The default temperature display is Fahrenheit
temperature. When the machine is in standby mode, press
the power button for 5 seconds to switch to Celsius
temperature. When the machine is running, it shows the
temperature and humidity of the inlet air and outlet air.
Defrosting Indicator: When the machine is defrosting, this indicator turns on.
After defrosting, it turns off.
Water Full Indicator: When the water pump is full of water, the indicator light turns
on to remind the user to drain.
Memory Function: If there is a power outage or the unit shuts off ,it will auto restart to its
original settings except timing ,once power is restored .
Note :
When humidity of air inlet ≥ setting humidity data +3%RH ,and the compressor is out of 3
minutes delay start protection , the fan will start immediately and the compressor will start
in 3 seconds later.
When humidity of air inlet ≤ setting humidity data -3%RH , the compressor will stop working
immediately ,and the fan will stop working in 1 minute later.