Instructions / Assembly
Drain outlet/External water pump inlet
Water Pipe
I: Water pipe drainage method
Operation instructions: When using the water pipe drainage method, connect the water pipe at the drain,
place the water pipe in place, place the other end of the water pipe at the drain, or at the drain sink,
or in the water storage container; turn on the machine to use the water pipe drainage method.
Dehumidifiers Adopt Drain by Gravity, the
collected condensation water can be drained
by gravity.When using gravity to drain:
1)Connect the drain hose to the Gravity
Drain Outlet;
2)Place the unattached end of the hose in
a suitable drainage facility. The drainage
facility should be lower than the drainoutlet
of the dehumidifier. (Ensure there are no
kinks or other obstructions that will stop
the water to flow.)
Note:
1)lf you use a bucket or other container
for water collection,check it regularly to
prevent overflows.2)Connecting a drain hose
that is too long is not recommended,as it
may cause water to back up, causing a leak.
3)lf the drain hose is too long, water may not
drain completely.which can lead to stagnant
water and mildew building up inside the hose.
4)Before moving the dehumidifier, make sure
the condensed water inside is completely
drained to avoid water leakage.
Drainage Method
17