Use and Care Manual

OL70-D056CW
DRAINAGE
4
Instruction Manual
Automatic/Pump Drainage
Take off the screw blocking the drain hole for automatic/pump drainage, which is located on the dehumidifier’s side panel.
Plug a PVC drain hose through the screw into this hole to enable automatic drainage. You may connect the other end of the hose to any drainage area.
The pump will automatically drain off water when its tank is full.
Pressing the “DRAIN” button can drain off water regardless of the tank’s status (even when the tank isn’t full). The pump will operate for 30 seconds and automatically shut down. Repeatedly
press this button to drain the unit completely.
WARNING: the end of the hose should not be submerged in water to prevent it from being blocked or damaged.
If the drain is located above the dehumidifier, the maximum capacity of the water pump is 5 m. If the water is drained downwards, there is no limit for the distance. The width of the
water hose is 12 mm.