Use and Care Manual

13
8.ERROR CODE
(1) “E1”: If the temperature sensor got failure, it will show “E1”. The
system works in circle of dehumidification for 30 minutes and
defrosting for 15 minutes. We should replace the faulty temperature
sensor with a new one.
(2) “E2”: If the humidity sensor got failure, it will show “E2”. The humidity
adjusting button will not work. The system works in circle of
dehumidification for 30 minutes and defrosting for 15 minutes. We
should replace the faulty humidity sensor with a new one.
(3) “CL”: When the room temperature 41˚F, it will show ”CL”, the
machine stops running.
(4) “CH”: When the room temperature 100˚F, it will show “CH”, the
machine stops running.
(5) “LO”: When the room humidity 20%RH, it will show “LO”, the
machine stops running.
(6) “HI”: When the room humidity≥95%RH, it will show “HI”, the
machine is working normally.
9.MAINTENANCE
9.1 Clean the machine with a soft wet cloth.
9.2 Pull the louver on the front panel out to gain access to the
filter.
9.3 Remove the filter mesh out of the unit.
9.4 Use a clean rag to adsorb the dust on the filter mesh surface.
If the filter is extremely dirty, use tap water to flush the filter. Fully
dry the filter before putting it back into the air inlet fence. A clean
filter can increase the machine’s capacity.