Use and Care Manual

12
set is available.Press continuous mode to switch to normal mode,
continuous mode light is off, humidity set is operational.
7.2 Accessories
1)Water Pipe 1pcs
2)Instruction manual 1pcs
3)Pushing Handle 1pcs
4)Fixed screw 2pcs
5)Water plug 1pcs
7.3 Operation
1) If the water tank is full for 5 minutes, alarm goes on, water tank light
turns red, buzzer rang 15 times, the compressor and the fan stop, after
emptying the water tank, machine automatically switch to the previous
mode, the self-protect of
compressor will start after 3 minutes. Alarm will
stop in 3 seconds after the water tank was emptied and put back, the fan
and the compressor will start in 3 minutes.
2) Compressor will not need 3 minutes for self-protect if it is the first time
to start the machine, press “POWER” to turn off the power; turn on the
power, press “POWER”, the compressor will start immediately.
3) The system has auto memory. When all the mode setting has been
finished, if there is sudden power cut durin
g operation, or the power jack
slips out, the system may store the current status before the power is cut
and enter the previous operation mode before power cut automatically
after power is supplied.
7.4 Defrost Function
1) Environmental temperature 41˚F, or environmental
temperature >100˚F, compressor and fan stop.
2) Defrost requirement:
Compressor runs for 30 minutes, temperature
sensor senses the temperature 30˚F(last for 10 seconds),
compressor stops, defro
st starts,fan continues, defrost light turns on,
when the pipe temperature goes to 41˚F or the defrost lasts for 15
minutes, defrost stops.
Note: during defrost, light won’t be off until the defrost is over.