Use and Care Manual
Table Of Contents
11
will return to current humidity after 10 seconds. Press this button for a
while to show the temperature.
(3)
In normal mode, press this button to increase the humidity, humidity
increase 5%RH with each press, buzzer rang each time with the press,
press the button for 1 second can increase the humidity continuously;
press this button to set the time after pressing “TIMER”.
(4)
In normal mode, press this button to decrease the humidity, humidity
decrease 5%RH with each press, buzzer rang each time with the press,
press the button for 1 second can decrease the humidity continuously;
press this button to set the time after press “TIMER”.
Note:
1) The default humidity is 50%RH, the increase and decrease is as
follow:
20%-25%-30%-35%-40%-45%-50%-55%-60%-65%-70%-75%-80%-85
%-90%
2) Environmental humidity and machine set humidity will decide the
status of compressor and fan as follow:
Environmental humidity≥machine set humidity+3% ,compressor and fan
start running.
Environmental humidity<machine set humidity+3%,compressor and fan
stop running.
Press continue button in continuous mode, switch to normal
dehumidification mode, set the humidity manually.
(5)
Continuous mode---(display screen shows current humidity) the machine
keeps running, continuous mode light is on, humidity set is invalid, time