Introduction and Overview CONGRATULATIONS, you have just passed to the next higher level of protection, the one for your home and its belongings against violation and theft. Although an alarm system does not constitute a full guarantee against those threats, it provides a clear discouraging aspect. The EDEN HA2000 alarm system was created according to the following principles: - Easy installation: The system can be installed by anyone. It does not require any specific technical knowledge on alarms.
Kit Contents I. z 1 x PIR Detector HA2000P z 1 x Keypad HA2000K z 1 x RTC Dialler HA2000RTC z Extra Fixing pack z Batteries HA2000 The Alarm System HA2000 should contain the following components: z z z z 1 x LCD Control Panel (20 Zones) 1 x PIR Detector HA2000P 1 x Door Contact HA2000M 1 x Remote Control HA2000R 3.6V ½ AA Size Lithium battery for Door Contact z Installation & Operating Manual z Fixing pack z 1*3 V CR2032 Lithium z Batteries II.
PLANNING OF THE INSTALLATION As there is no wiring work, a wireless alarm system is especially easy to installed. Easy to make any modification also, as it will be very easy to move a detector in order to put it at a more efficient location, if necessary. For that reason, you do not need to worry about a perfect installation before use. Before any installation, it is important to evaluate carefully the intrusion risks within your house, and particularly the external openings.
The main alarm was placed in the hall. Generally, it should be put in a central area of the house and not visible from the windows. current screen and returning to the previous screen etc. 6. “OK” Key The HA2000E outdoor flash-siren warns immediately the neighborhood in case of triggering the alarms. The HA2000I internal radio siren allows not only to protect the main alarm (silence mode) but also to deafen the thieves or burglars.
beep. “Alarm On” will be displayed on the first line of the screen indicating the system is in Away mode (this is the default mode) Step 3. Press “ 0 “ key on the keypad, the display will show. E n t e r C o d e * _ _ _ Step 4. Key in the remaining “000” (default PIN code) within 10 sec. Step 5. Press “OK”. You will hear 2 short beeps and the display will show. A l a r m O f f The system is now in Disarmed mode.
following items can be selected. 9 9 9 Configuring your system I. Entering Programming mode The Programming mode is for you to configure the system. If the system is in Disarmed “Alarm off” mode, to enter the Programming mode, follow the steps below. Step 1. Press “ ” key. ∇ the screen will prompt you to enter the Master PIN code. Step 3. Press “OK” ∇ The following message is displayed for 2 sec.
z “User2” is used to regularly arm and disarm the system. z The “Cleaner” code can only be used to Away Step 5. Follow the same steps to program and activate User2, Cleaner and the Temp PIN codes respectively. arm the system. z The “Temp” code will only disarm and Away arm the system once. When away arming, the system will automatically erase the code. ) z Each PIN code consists of 4 digits and only User1 PIN code is activated with “0000” as factory default.
1 0 2. Master PIN code z Master PIN code is used for accessing the programming mode and it is set to “0000” as factory default. Before you set your own Master PIN code, “0000” has to be keyed in every time it is required. z Use “S”,“T” keys to switch between options. z Press “OK” to confirm. z 10 sec. is set as factory default. ) z To set your Master PIN code Step 1. Use the arrow keys to select “Master PIN code” and press “OK” E n t e r N e w C o d e . . . . Step 2.
This is for you to decide whether to enable or disable the Control Panel Tamper protection. z “Chime Low” is set as factory default. C . U . C . U . T a m p e r T a m p e r O n O f f z Press “S”,” T” keys to select the option. z Press “OK” to confirm. z “C.U. Tamper Off” is set as factory default. ) Remember to enable the Tamper protection after all the programming and installations are completed. 8.
sec. in case any fault condition persists. 13. Language Choose the language as you would like for the control panel. E F N D n r e e g a d u l n e t i ç r s s a l c h i s a n d s h z Press “S”,” T” keys to select the option. z Press “OK” to confirm. III. Add/ Delete Device If “Devices +/-“ is selected in Programming Main menu, the “Device +/-“ menu is displayed. From here you can add or delete devices and edit devices zone names.
The PIR detector is in zone 3, programmed for burglar mode with an Instant attribute and is named “Hall”. Remote Controller HA2000R The Remote Controller is used to remotely arm or disarm the system, activate the panic alarm, and put the system in the "HOME" mode. z Identifying the parts 1. BUTTON Pressing this button will put the system into the Armed mode. 2. BUTTON Pressing this button for 3 seconds will trigger the panic alarm regardless of whether the system is Armed, Disarmed or Home. 3.
The example screen represents the Remote Controller is installed in zone 3 and it is a “Personal Attack” Remote Controller. z Device Naming Detectors can be given names and location descriptions to help understand system events. The devices can be named when first installing them or by editing them afterwards, the procedure is similar for both situations. When the “Enter zone NAME”, “Enter zone name” screen is displayed, the keypad can be used to enter text, similar to “texting” with a mobile telephone.
z When the Open Contact is in Low battery condition, every time the Open Contact is activated (door opened or door closed), the LED will light. z When the cover is opened and the tamper switch is violated, the LED will light. z When the tamper condition persists, every time the Open Contact is activated, the LED will light. 1. LED indicator 2. Learn / Test button This button is used for testing the radio performance and for learning purpose. 3.
programmed). it will work in different modes. StepA5. After the detected Open Contact is confirmed, you are requested to choose between “Burglar”, “Home Omit”, “Entry”, “Home Delay”, “24 Hour” and “Fire” device mode. B H E H 2 F u o n o 4 i r m t m r g l a r e O m i t r y e D e l a y H o u r e ) “B” for Burglar Open Contact z When the system is in Arm mode or Home mode, if a “Burglar” Open Contact is triggered, a “Burglar Alarm” will be activated immediately.
“Burglar”, “Home Omit”& “Home Delay” device mode, but not available with “Entry” device mode. While “24 Hour”, “Fire” device mode are assignd to have Instant attribute by nature. StepA7. Make a selection and press “OK”. The screen will change to: E n t e r z o n e N A M E . . . . . . . . . . . . . + O K StepA8. You are now invited to give a name or location description to the device to help understand system events.
If the Control Panel doesn’t receive the Supervisory signals transmitted from a certain PIR, an “Out-Of-Order” fault message will be generated. z Sleep Timer The PIR has a “sleep time” of approximately 1 minute to conserve power. After transmitting a detected movement, the PIR will not retransmit for 1 minute; any further movement detected during this sleep period will extend the sleep time by another minute. In this way continuous movement in front of a PIR will not unduly exhaust the battery.
following Step A6 for adding the Door Contact. ) Control Panel will give a Personal Attack alarm when the button is pressed for more than 2 seconds. StepB7. Make a selection and press “OK”. The screen will change to: E n t e r z o n e N A M E . . . . . . . . . . . . . + O K StepB8. You are now invited to give a name or location description to the device to help understand system events. You can enter up to 12 digits as you please for the name followed by “OK” or just press “OK” for no name.
Control Panel will give a Personal Attack alarm when the Panic Button is pressed for more than 2 seconds. ) ) “M” for Medical Button E n t e r z o n e N A M E . . . . . . . . . . . . . + O K Step E7. You are now invited to give a name or location description to the device to help understand system events. You can enter up to 12 digits as you please for the name followed by “OK” or just press “OK” for no name. Please see section “Device Naming” for details. StepE8.
) completed. Remote Keypad is not assigned to any mode ) Smoke Detector is assigned to Fire mode automatically Device Mode by Alarms Type of Device Mode Arm Home Instant Delayed Chime Mode Mode (I) Burglar (B) Detector supervised in Arm and Home mode √ √ √ Home Omit (O) Detector not supervised in Home mode √ √ √ Entry (E) Detector delayed in Arm and Home mode.
D C P I R Z o n e 0 2 B H a l l . . . . . . . . Z o n e 0 3 O I . . . . . . . . . . . . Step 2. Press “OK” when the required device is found. The display will prompt you to reconfirm. Step 3. Press “OK”. z z R C Z o n e 0 1 P J o h n . . . . . . . . D C Z o n e 0 2 B H a l l . . . . . . . . P I R Z o n e 0 3 O I . . . . . . . . . . . .
C o n f i r m C o n f i r m O n O f f z Siren A/T On, Siren A/T Off The Siren tamper switch can be enabled and disabled remotely. z Add Siren z If there is any detector or Remote Controller has been added already, Step 1. Put the Siren into learn mode (Refer to Siren Operational Manual). Step 2. Move the cursor to the position “Learn Siren”. Step 3. Press “OK”. Step 4. The Control Panel will then sound a long beep and transmit Learning code to the Bell Box.
button on the Remote Controller or triggering the sensor, if the Control Panel received the signal, it will sound a high volume door chime and the display will show you which sensor with its description is reacting. P I R z Z o n e 0 2 B H A L L D O O R The message will be displayed until replaced by another test signal, with an acknowledgement high volume chime.
system, it will beep once and the strobe will flash once after the Exit Delay has expired. A flashing cursor will underline the first character of the menu selected; the total menu list consists of: A H W L w o a o a y m e l k g A r m A r m T e s t These items can be scrolled through by using the “S”, “T” keys. II. Alarm ON Mode 1. Arming the system If the system is in Disarmed mode, to arm the system. Step 1. Enter your PIN code and press “OK” within 10 seconds.
the Remote Controller. Keypad or Remote ) 2. Door Chime If an “Entry” Door Contact or PIR Detector is triggered, the Control Panel will sound a ding-dong door chime, (if Door Chime function is enabled) The Home mode allows the home to be Armed so that no one can get inside without first disarming the system, yet the person already inside the house can move freely without self triggering the alarm. 1. Entering the Home mode To put the system into the HOME mode: Step 1.
z During the Entry Delay period, if a sensor with Instant attribute is triggered, the Control Panel will activate the alarm immediately, otherwise the control Panel will not respond. 2. Disarmed Mode attribute is triggered again, the Control Panel will activate the alarm immediately. z If “Home Delay” Door Contact or PIR is triggered, the Control Panel will ignore it. z If a Door Contact or PIR with Non-Instant attribute is triggered, the Control Panel also ignores it.
will show the source of the alarm: Panel is sounded. 2. The Control Panel will sound swept frequency alarm tone in high volume. A l a r m e d b y P I R Z 0 1 . . . . . . . . . . . . “Water Alarm” The sensor which triggers the alarm is displayed on the top line while its zone number and name (if entered) are displayed on the second line. 1. There are two types of Water Alarm: z For Internal Alarm Water Detector--an alarm condition where the Control Panel is activated.
z The Control Panel is capable of detecting following fault events: 9 Control Panel Low Battery 9 Device Low Battery 9 Device and Control Panel Tamper 9 Interference 1. Fault Message Display z When any fault situation persists, the Control Panel will respond as below when it is in Disarmed mode: z A warning beep will sound at every 30 seconds (if “Warning Beep On” is set). z When any key is pressed, the Control Panel will sound a two-tone fault sound and the fault message will be displayed.
“Tamp” means Tamper where “Rest”. is short for restore. H o m e I n t e r f e r e n c e 4. Device Low Battery When a device low battery condition is detected, the Control Panel only sounds a warning beep every 30 seconds and displays a fault message when it is accessed in Disarm mode. L B . R e s t o r e H A L L P I R Z 0 2 T a m p . R e s t . K I T C H E N VIIII.
z Mounting Method z Enable the Control Panel Tamper protection in the Programming mode under General Setting’s menu after all the programming and installations are completed. II. PIR detector HA2000P After the PIR is learnt-in, put the Control Panel into “Walk Test” mode, hold the PIR in the desired location, and press the Test button to confirm this location is within signal range of the Control Panel. When you are satisfied that the PIR work in the chosen location, you can proceed with installation.
Step 9. Insert the wall plugs if fixing it into plaster or brick. Step 10. Screw the base into the wall plugs Step 11. Screw the cover back onto its base degreaser. Step 2. Remove the protective covering from one side of the double-sided adhesive pad and firmly apply to the back of the device. Step 3. Next remove the other cover and firmly press the item onto the desired location.
enable the LED indicator to flash every time the Door Contact is operated. Contact remotely. z More than one window and door can be protected by a Open Contact using the additional magnet and extension magnet switch. The switches must be wired to the auxiliary terminal block as shown: z Any device with N.C.
Extension Terminal alone with the internal magnet switch being bypassed or to use both of them together. If you choose to have both of the internal magnetic Switch and Extension Terminal work together, then. z When the protected door is being opened or the enteral device is triggered, the Open Contact is activated and will transmit a violation signal However The Open Contact will transmit a “Door Closed” or “Restored Signal” only affer the protected door and the violated device being restored.
Step 3. Release both the “S” key and the “RESET BUTTON” when a long beep is heard, “Enter Code” will be displayed. Step 4. Press the “ reset. ” key and all codes will be Step 1. Disable tamper protection by putting the Control Panel into Programming Mode. z If “ ” key is pressed, then the unit will revert to normal alarm on mode. z If more than 17 incorrect keys entered, then the unit will revert to normal alarm on mode.
-press both 4 and 6 to trigger fire alarm 13. A Key -press both 1 and 3 to trigger panic alarm 14. Mounting Hole z Orange LED indicates Away Mode z Orange LED flash indicates Home Mode. z Green LED indicates Disarm Mode. z Green LED flash indicates failure due to the following reasons: 15. Tamper Swtich ¾ No response sent by the control panel within 4 seconds. 16. Numeric Key ¾ PIN code was incorrect. ¾ Request for “Home” mode during “Arm” mode. ¾ Request for “Force” arm.
z with regular signal transmissions for the Control Panel to display the status accordingly. z Using the 2 mounting holes as a template, mark off the hole positions in the most appropriate place. Before shipment, the battery is pre-installed by the factory. z Insert the wall plugs if fixing into plaster or brick surface. z Screw the HA2000K onto the wall plugs. z Replace the 2 slide-out sections. z Power Saving Feature: z When idle, HA2000K is in “standby” mode and uses no power.
Press “#”, HA2000K sounds a long beep ” twice to exit Test mode and Step 6. Press” the installation is completed.
Alarm record Zone Complete the following information during installation for future reference when adding to your system and to assist Trouble Shooting. Detector Type(s) Location Type of device mode Final Exit Entry Delay Chime Away Arm Home Arm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 You may make a note of your User Password and Installer Password below.
• • • • • • • • • • • • • • • • Rolling code for remote controls and keypads. Fixed code for other accessories with over 16 millions possible combinations. Silent alarm possible. Anti jamming function, programmable. Arm/disarm confirmation on outdoor & indoor siren. Doorbell function. Keypad locking in case of multiple erroneous codes. Volume set up for integrated speaker sound confirmations. Tamper protection connectable for maintenance.
• Weight : 190g Outdoor Siren / Flashlight HA2000E • • • • • • • • • • • 8 functions: Intrusion, Fire, arming + disarming confirmation, weak batteries, tamper, tamper fault, anti jamming. Noise level: 104db @ 1m Sound types : Bips (Arm, Disarm, Weak battery, Tamper fault) + Siren (Intrusion & Fire) Flash type : 3 high power LEDs Weak battery signal thru bips and flash maximum Siren timing: 1/5/10 min or 1 s in test mode Battery life: over 3 years. 1 month after weak battery signal.
PROBLEM? 7 Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to help you make a perfect installation.