Corporation Stereo System User's Manual

OPERATING INSTRUCTIONS FOR GAMBIT DE-ESSER/COMPRESSOR DS1-MK3 TECHNICAL DATA
Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster Page 33
+41 44 940 20 06 +41 44 940 22 14 http://www.weiss.ch weiss@weiss.ch
Addendum to the Manuals of the Gambit Series DS1,
DS1-MK2 and DS1-MK3 DeEsser / Compressor / Limiter
The graphs on the pages below have been made to convey a better understanding of the dynamic pa-
rameters of the Gambit DS1 DeEsser/Compressor.
Please also read the appropriate pages in the DS1/DS1-MK2/DS1-MK3 manual to have a proper under-
standing of the sidechain process.
The test signal is a repeating sine wave burst with a certain "on" and a certain "off" level. The frequency
of the sine wave is above 10kHz (period less than 100µs), so there is no influence of the sine wave fre-
quency on the timing behaviour.
The table below shows the timing parameters set on the DS1. For the static parameters a threshold of -
20dB, a 1000:1 ratio and no softknee have been chosen. The peak / RMS time parameter was set to peak
measurement.
Figure Preview Attack Rel.Delay Rel.Fast Average Rel.Slow burst duty cycle
1 bypass
2 20µs 20ms 20µs 200ms 800ms 1s 50%
3 63ms " " " " " "
4 " " " " " 200ms "
5 " " 5ms " " " "
6 " " 20ms " " " "
7 " " " 25ms " 500ms 0.5%
8 " " " " " " 2%
9 " " " " " " 5%
10 " " " " " " 10%
11 " " " " 40ms " 0.5%
12 " " " " " " 2%
13 " " " " " " 5%
14 " " " " " " 10%