Maintenance
Should the Engine Stop While Operating:
•Checkwatersupply:
a. Is city water valve fully open?
b. Is valve on saw console open?
c.Ifyouareusinggravityfeed,checktheow.
d. If using a tank, is it empty?
•Checkfuellevelinthegastank.Donotoverllthegastankandneverrefuelahotengine.Ifrefuelingisnecessary
duringoperation,allowtheenginetocooldownrst.
•Checkoillevel.Note: Some engines are equipped with an oil pressure switch that shuts off the engine in the event
the oil level drops below acceptable levels.
•WastheE-Stopaccidentlypushedin?
•Afterdeterminingandxingthesourceoftheproblem,followalloftheStarting the Engine instructions on page 6.
Ifnoneoftheabovesituationscorrecttheproblem,discontinueuseandcontactaqualiedrepairprofessional.
The following maintenance instructions are brief explanations
ofsomeoftheitemssuggestedintheMaintenanceSchedulechartonpage15.
These instructions are not replacements for the
Engine Manufacturer’s Maintenance Instructions.
Changing the Water Pump Fuse if Equipped:
The Water Pump Fuse is located inside saw unit. (Figure 10)
• Toaccessit,unscrewtheboltandopenthegastankdoor.
• Reachinandndthefusecap.Itislocatedinfrontofthewaterpump.
• Twistandpullapartthecapandremovethefuse.
• ReplaceitwithaAGC10250Vorequivalentfuse
Figure 10
Fuse
Water
Pump