User's Manual
Table Of Contents
- Statement
- Responsibility of the Manufacturer
- Terms Used in this Manual
- Chapter 1 Intended Use and Safety Guidance
- Chapter 2 Overview
- Chapter 3 Installation of Telemetry Monitoring System
- Chapter 4 Basic Operations
- Chapter 5 Patient Management
- Chapter 6 Patient Sector
- Chapter 7 Viewing Single Bed
- Chapter 8 Setting Telemetry Transmitters via MFM-CMS
- Chapter 9 Review
- Chapter 10 System Setup
- Chapter 11 Alarm Management
- Chapter 12 Alarm Information
- Chapter 13 Printing
- Chapter 14 Database Management
- Chapter 15 Monitoring ECG
- 15.1 Overview
- 15.2 ECG Safety Information
- 15.3 ECG Display
- 15.4 Selecting Calculation Lead
- 15.5 Changing Size of ECG Waveform
- 15.6 Changing ECG Filter Settings
- 15.7 ECG Alarm Settings
- 15.8 Monitoring Procedure
- 15.9 Installing Electrodes
- 15.10 Setting Alarm Source
- 15.11 Smart Lead Off
- 15.12 Setting Pace Status
- 15.13 ECG Calibration
- 15.14 ECG Waveform Settings
- 15.15 ST Segment Monitoring
- 15.16 Arr. Monitoring
- Chapter 16 Monitoring RESP
- Chapter 17 Monitoring SpO2
- Chapter 18 Monitoring PR
- Chapter 19 Using Battery
- Chapter 20 Safety
- Chapter 21 Care and Cleaning
- Chapter 22 Maintenance
- Chapter 23 Warranty and Service
- Chapter 24 Accessories
- A Product Specifications
- B EMC Information
- C Default Settings
- D Abbreviation
Telemetry Transmitter User Manual Patient Management
5.3 Switching Patient sector
For a disconnected patient sector (refer to Section 2.5.2.2 Patient Sectors), click anywhere in
it and choose a patient to be assigned to this section from the patient list.
For a patient sector which is either improper offline or networked (refer to Section 2.5.2.2
Patient Sectors), select Show from the list on the patient sector (refer to Sector 6.3 Menu in
the Patient Sector), and choose another telemetry transmitter from the patient list; the chosen
telemetry transmitter will be displayed in this patient sector.
5.4 Discharging a Patient
When the monitoring on a patient is completed, you need to discharge this patient by any of the
following methods:
Choose Discharge from the menu in the patient sector (refer to Section 6.3 Menu in the
Patient Sector).
Choose Patient Mgmt > Discharge on the auxiliary screen.
Discharge the patient via the Review window. Refer to Section 9.1.1 Patient Review.
The operation of discharging a patient will cause the patient offline from the MFM-CMS, and
there will be no patient admitted in the related patient sector. The discharged patient will be
shown in the history patient list. Refer to Section 9.1.2 History Patient Review.
5.5 Transferring a Patient
Select Patient Mgmt >Transfer on the auxiliary screen, and you will see a list of online patients.
From this list, select a patient whose bed will be considered as the destination bed and click OK,
and then the current patient will be transferred to the destination bed.
NOTE:
Transferring a patient to the destination bed will at the same time discharge the selected
patient on the destination bed.
5.6 Monitoring Statistics
The monitoring statistics of the selected patients will be shown in the patient management
window. The monitoring statistics covers the total monitoring time for waveforms and trends, the
number of alarm events.
Click Analysis, the system will:
Analyze the number of high and low limit alarms for each physiological parameter and
analyze the percentage of the limit alarms of the parameter in all limit alarms.
Analyze the number of arrhythmia events for each type of arrhythmia and analyze the
percentage of a certain type of arrhythmia.
Analyze the average value, maximum/minimum value, and measure time of the
maximum/minimum value for the trend values.
- 35 -