User's Manual
Table Of Contents
- Statement
- Responsibility of the Manufacturer
- Terms Used in this Manual
- Chapter 1 Intended Use and Safety Guidance
- Chapter 2 Overview
- Chapter 3 Installation of Telemetry Monitoring System
- Chapter 4 Basic Operations
- Chapter 5 Patient Management
- Chapter 6 Patient Sector
- Chapter 7 Viewing Single Bed
- Chapter 8 Setting Telemetry Transmitters via MFM-CMS
- Chapter 9 Review
- Chapter 10 System Setup
- Chapter 11 Alarm Management
- Chapter 12 Alarm Information
- Chapter 13 Printing
- Chapter 14 Database Management
- Chapter 15 Monitoring ECG
- 15.1 Overview
- 15.2 ECG Safety Information
- 15.3 ECG Display
- 15.4 Selecting Calculation Lead
- 15.5 Changing Size of ECG Waveform
- 15.6 Changing ECG Filter Settings
- 15.7 ECG Alarm Settings
- 15.8 Monitoring Procedure
- 15.9 Installing Electrodes
- 15.10 Setting Alarm Source
- 15.11 Smart Lead Off
- 15.12 Setting Pace Status
- 15.13 ECG Calibration
- 15.14 ECG Waveform Settings
- 15.15 ST Segment Monitoring
- 15.16 Arr. Monitoring
- Chapter 16 Monitoring RESP
- Chapter 17 Monitoring SpO2
- Chapter 18 Monitoring PR
- Chapter 19 Using Battery
- Chapter 20 Safety
- Chapter 21 Care and Cleaning
- Chapter 22 Maintenance
- Chapter 23 Warranty and Service
- Chapter 24 Accessories
- A Product Specifications
- B EMC Information
- C Default Settings
- D Abbreviation
Telemetry Transmitter User Manual Basic Operations
Method 2:
Select System Setup > User Maintain, and enter the password ABC; select Other Setup.
Select Shut Down: the MFM-CMS as well as the operating system will be shut down.
Select Return to Windows: you will exit from MFM-CMS, but the operating system will
not be shut down.
WARNING
1 Shut down the system by strictly observing the shutdown procedure to avoid serious
result.
2 Although UPS is an optional configuration of this system, if you really force to turn off
the UPS, it results in system failure and hence affects the operation of next time.
3 If power cut-off occurs, turn off the system before the UPS exhausts its electricity.
CAUTION
Hospitals without a stable power source should use a UPS to provide power to the
MFM-CMS. The UPS must not be turned off. When there is a power failure, the system
should be shut down by following the specified shutdown procedure before the UPS is
exhausted. If the system has a sudden power failure, system failure may occur and
consequently the system may not work correctly next time or even has a serious result.
NOTE:
If you forget the password, please contact the technical representative of EDAN.
- 33 -