Data Sheet

2-9. Hold Up Time
8.3mSec.@ Normal line, with full load.
2-10. Rise Time
50 mSec.,@ 100-240VAC input, with full load from 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage in less than 3 SEC. from
AC apply to 110Vac start up.
2-12. Harmonic Standard and Power Factor
The adapter complied with IEC 61000-3-2 class D harmonic standard while input power
over than 75W. The P.F. shall >0.95 @100Vac input and >0.9 @240Vac input.
3-0. Output Requirements
3-1. Output Voltage and Current
3-2. Load Regulation
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at any
frequency up to 1KHz(duty 50%).
3-4. Ripple Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Ripple/Noise
+23V
1% max. of rated output voltage
Input condition : for rated voltage , Output condition : for max load
Ripple / Noise: 60Hz ripple + switching ripple and noise
Ripple & Noise are measured at the end of output cable which are added a 0.1uF
ceramic capacitor and a 47uF electrolytic capacitor
Output Voltage (Vdc) Current Min.(A) Current Max.(A)
+24V 0 8.33
Voltage (Vdc) Tolerance (%)
+24V +5/, -5