Data Sheet
Ripple & Noise are measured at the end of output cable which are added a 0.1uF
ceramic capacitor and a 47uF electrolytic capacitor
3-5. Over Voltage Protection
150% Max. of rated voltage.
The output voltage shall shutdown and latch-off when OVP is occurred.
3-6. Over Current Protection
110%-180% of rated output current.
The adapter will enter protection at overload mode and no damage. It will enter into
normal condition if the fault condition is removed.
3-7. Stability
2% Max. at constant load with constant input (after 30 minutes of operation).
3-8.Temperature Rise
Less than 45℃ on top/bottom case at normal AC input & 80% load of DC output at
environment temperature 25℃.
3-9. Drop-out (Power Line Disturbance)
Output voltage shall remain within the specified regulation range, through the absence of
a line input during 1/2 cycle, at full load and normal AC line input
3-10. Voltage Isolation
The DC ground will be isolated from the AC neutral and AC line.
4-0.Reliability
4-1. MTBF ( MIL-HDBK-217F )
The power supply shall be designed and produced to have a mean time between failure
( MTBF) of 100,000 hours at 25 degrees C.
5-0. Environment
5-1 Temperature
a. Operating : 0℃ to 40 ℃
b. Storage : -20 to 85 ℃
5-2 Humidity
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %