Data Sheet

3-4. Ripple Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Ripple/Noise
+24V
1.5% max. of rated output
voltage(P-PK)
Input condition : for rated voltage , Output condition : for max load
Ripple / Noise: 60Hz ripple + switching ripple and noise
Ripple & Noise are measured at the end of output cable which are added a 0.1uF
ceramic capacitor and a 47uF electrolytic capacitor
3-5. Over Voltage Protection
150% Max. of rated voltage.
The output voltage shall be shutdown and latch-off when OVP occurred.
3-6. Over Current Protection
110%-170% of rated output current.
The adapter can withstand continuous short at DC output and no damage.
It will enter into normal condition if the fault condition is removed.
3-7. Stability
2% Max. at constant load with constant input (after 30 minutes of operation).
3-8.Temperature Rise
Less than 45 on top/bottom case at normal AC input & 80% load of DC output at
environment temperature 25.
3-9. Drop-out (Power Line Disturbance)
Output voltage shall remain within the specified regulation range, through the absence of
a line input during 1/2 cycle, at full load and normal AC line input
3-10. Voltage Isolation
The DC ground will be isolated from the AC neutral and AC line.